Headlines 26/11/2016 17:13 CH

Regulations on workplace in effect as of December 01, 2016

Thu Hiền

The following 9 prominent national technical regulations on workplace shall come into force as of December 01, 2016:

1. Permissible exposure levels of noise in the workplace

QCVN 24:2016/BYT annexed to the Circular No. 24/2016/TT-BYT defines the permissible exposure levels of noise in the workplace:

- Permissible exposure time for sound pressure levels:

+ In 01 minute: not exceeding 112 dBA

+ In 01 hour: not exceeding 94 dBA

+ In 08 hours: not exceeding 85 dBA

- Permissible sound pressure levels at work positions:

+ Direct or on-site work or production positions: not exceeding 85 dBA

+ Functional, general administrative, accounting and planning departments: not exceeding 65 dBA

+ Brainwork, research and design, statistics, computer programming, theory testing and data processing divisions: not exceeding 55 dBA.  

2. Permissible levels of lighting in the workplace

QCVN 22:2016/BYT annexed to the Circular No. 22/2016/TT-BYT defines the permissible levels of lighting in the workplace. The following minimum illumination levels in the workplace thereof apply:

General indoor area:

- Lobby, passageway and corridor: minimum illumination level of 100 lux

- Staircase, elevator, escalator: minimum illumination level of 150 lux

- Locker room, basin room, bathroom, water closet: minimum illumination level of 200 lux

Office:

- General office, archive room, photocopy room, conference room: minimum illumination level of 300 lux

- Typing and data processing room: minimum illumination level of 500 lux

3. Permissible levels of temperature and humidity in the workplace

QCVN 26:2016/BYT annexed to the Circular No. 26/2016/TT-BYT defines the permissible value of microclimate in the workplace. The following permissible levels of temperature and humidity apply:

- Easy work (associated with sitting, standing, walking, mostly hand movements and burning of 120 to 150 kcal/hour):

+ Temperature range: 20 to 34oC

+ Air humidity: 40 to 80%

- Average work (associated with standing, walking, moving and handling of items weighed less than 1 kg in standing and sitting positions, carrying of items weighed less than 10 kg, burning of 151 to 250 kcal/hour):

+ Temperature range: 18 to 32oC

+ Air humidity: 40 to 80%

- Heavy work (working frequently at standing or walking positions, moving and handling of items weighed more than 10 kg, burning of more than 250 kcal/hour):

+ Temperature range: 16 to 30oC

+ Air humidity: 40 to 80%

4. QCVN 21:2016/BYT annexed to the Circular No. 21/2016/TT-BYT on high frequency electromagnetic - permissible exposure level of high frequency electromagnetic intensity in the workplace.

5. QCVN 23:2016/BYT annexed to the Circular No. 23/2016/TT-BYT on ultraviolet radiation - permissible exposure levels of ultraviolet radiation in the workplace.

6. QCVN 25:2016/BYT annexed to the Circular No. 25/2016/TT-BYT on industrial frequency electromagnetic fields - permissible exposure level of industrial frequency electromagnetic fields in the workplace.

7. QCVN 27:2016/BYT annexed to the Circular No. 27/2016/TT-BYT on vibration - permissible levels of vibration in the workplace.

8. QCVN 29:2016/BYT annexed to the Circular No. 29/2016/TT-BYT on ionizing radiation - permissible exposure limits of ionizing radiation in the workplace.

9. QCVN 30:2016/BYT annexed to the Circular No. 30/2016/TT-BYT on X-ray radiation - permissible exposure limits of x- ray radiation in the workplace.

2.824

More headlines

Most Viewed

Address: 17 Nguyen Gia Thieu street, Ward Vo Thi Sau, District 3, Ho Chi Minh City, Vietnam.
Phone: (+84)28 3930 3279 (06 lines)
Email: info@ThuVienPhapLuat.vn

Copyright© 2019 by THƯ VIỆN PHÁP LUẬT
Editorial Director: Mr. Bui Tuong Vu

DMCA.com Protection Status